Precision-machined automotive engineering component
Automotive & Engineering Components Industry

Castomatch Global Pvt. Ltd.

43% Energy Savings
Achieved
43% Energy Saving Achieved

SaveCompAir delivered an impressive 43% reduction in compressed air energy consumption at Castomatch Global Pvt. Ltd., far exceeding the projected savings of 20% and the guaranteed savings of 15%. Through installation of a downstream pressure–flow control system, added receiver capacity, and network corrections, the plant achieved ~650 kWh/day savings and optimized its system pressure from 94–109 PSI down to 60–61 PSI.

Castomatch Global Pvt. Ltd.

Automotive Forging & Engineering
43%
Before SaveCompAir®
Operating Pressure94–109 PSI
Energy Consumption~1,500 kWh/day
Pressure StabilityUnstable
After SaveCompAir®
Operating Pressure60–61 PSI
Energy Consumption~850 kWh/day
Pressure StabilityStable
~650 kWh
Daily Savings
~2,27,500 kWh
Annual Savings
~₹22.75 L
Annual Cost Savings
~₹2.27 Cr
10-Year Savings

1. Plant Background

Industry
Automotive, Engineering Components
Pressure Band Before
6.5 to 7.5 bar
Energy Consumption Before
~1500 kWh/day

2. Problems Identified
(Audit Findings)

Devdeep Technologies conducted a complete compressed air network audit and found:

  • High pressure requirements (94–109 PSI)
  • All compressors running continuously to maintain pressure
  • Increasing energy usage and rising operational cost
  • Potential need for an additional compressor
  • Demand-side inefficiencies and high artificial air demand
  • Insufficient receiver capacity and network imbalance
Savings Identified: 20%
Guaranteed Savings Offered: 15%

3. SaveCompAir Solution
Implemented

Installed System:

  • Additional air receiver added for load balancing and system optimization
  • Line Corrections: Upgrades and rerouting in main compressor room
  • Placement: Controller installed before main header
  • Pressure Tests Performed At: 85, 80, 75, 70, 65 PSI – controller held setpoint accurately
  • Pressure Stability Achieved: ±1 PSI throughout the plant

Team validated that downstream machines experienced no pressure drop even at lower pressure settings.

4. Performance After
Installation

Before
94–109
PSI Plant Pressure
➡
After
60–61
PSI Plant Pressure

Additional Optimization Potential

  • Current pressure: ~60 PSI
  • Can reduce to 45 PSI for additional 10% savings

System Behavior

  • Controller stability: ±1 PSI
  • No pressure drop at Machine Shop even at lower pressures

5. Savings Achieved

Daily Savings

~310 kWh
Projected
~650 kWh
Actual

Percentage Savings

20%
Projected
15%
Guaranteed
43%
Actual Energy Savings

Annual Financial Impact

~2,27,500 kWh
Energy Saved / Year
~₹22.75 L
Cost Savings / Year
~₹2.27 Cr
10-Year Savings

6. Key Improvements

  • Downstream pressure now stable at ±1 PSI
  • Compressors no longer required to operate at high pressure
  • Avoided the need for an additional compressor
  • Lower artificial demand, decreased system losses
  • Network now operates at significantly lower pressure with zero drop at usage points