Robotic welding cell on an automotive stamping production line
Automotive & Metal Forming Industry

Dyna-K Automotive Stamping Pvt. Ltd.

48% Energy Savings
Achieved
48% Energy Saving Achieved

SaveCompAir delivered a significant 48% reduction in compressed air energy consumption at Dyna-K Automotive Stamping Pvt. Ltd., exceeding the guaranteed savings commitment of 25% and the projected 30% saving potential. Through downstream pressure stabilization, correct receiver optimization, and system-level corrections, the plant achieved ~918 kWh/day energy savings and lowered operating pressure by over 40 PSI.

Dyna-K Automotive Stamping Pvt. Ltd.

Automotive Forging & Stamping
48%
Before SaveCompAir®
Operating Pressure101–108 PSI
Energy Consumption~1,900 kWh/day
Pressure StabilityPoor
After SaveCompAir®
Operating Pressure65–66 PSI
Energy Consumption~990 kWh/day
Pressure StabilityStable
~918 kWh
Daily Savings
~2,98,000 kWh
Annual Savings
~₹34 L
Annual Cost Savings
~₹3.4 Cr
10-Year Savings

1. Plant Background

Industry
Automotive Stamping
Pressure Band Before
6.5 to 7.5 bar
Energy Consumption Before
~1900 kWh/day

2. Problems Identified
(Audit Findings)

The compressed air network audit conducted by Devdeep Technologies revealed:

  • High pressure fluctuations: 101–108 PSI across the network
  • Continuous operation of all compressors
  • Inefficient compressor distribution across locations
  • Need for additional compressor in future
  • Excessive daily energy usage
  • Substantial artificial demand due to higher pressure
  • Ineffective receiver sizing for the plant load
Savings Potential Identified: 30%
Guaranteed Savings Offered: 25%

3. SaveCompAir Solution
Implemented

Installed System:

  • Additional air receiver added for load balancing and system optimization
  • Line corrections in compressor room
  • Downstream control integrated before main header
  • System validated across multiple pressure tests (85, 80, 70, 65 PSI)
  • Verified pressure stability: ±1 PSI throughout the plant

4. Performance After
Installation

Before
101–108
PSI Plant Pressure
➡
After
65–66
PSI Plant Pressure
  • Current operating pressure: ~72 PSI
  • Plant can further lower pressure to 58 PSI for an additional 15% savings
  • No pressure drop at Foundry Shop even at lower setpoints

5. Savings Achieved

Daily Savings

~675 kWh
Projected
~918 kWh
Actual
+36%
Better Than Projected

Percentage Savings

30%
Projected
25%
Guaranteed
48%
Actual Energy Savings

Annual Financial Impact

~2,98,000 kWh
Energy Saved / Year
~₹34 L
Cost Savings / Year
~₹3.4 Cr
10-Year Savings

6. Key Improvements

  • Stable downstream pressure: ±1 PSI accuracy
  • Eliminated need for additional compressor
  • Significant reduction in artificial demand
  • Reduced compressor loading & operating hours
  • Lower pressure across network with no impact on production
  • Improved air availability at remote locations